NGSP Labnovation HbA1c Analyzer 4.3'' TFT Graphic Color Display For HbA1c Testing

Labnovation Technologies, Inc.
Contact Now

NGSP Labnovation HbA1c Analyzer 4.3'' TFT Graphic Color Display For HbA1c Testing

  • 1
  • 2

Brand Name : LABNOVATION

Model Number : LD-100

Certification : IFCC, NGSP, CE

Place of Origin : China

MOQ : 1

Price : Negotiation

Payment Terms : D/A, D/P, T/T

Supply Ability : 100 Units/Day

Delivery Time : 15-20 working days

Packaging Details : Carton

Test Range : 4%-15% (NGSP Unit)

Display : 4.3” TFT graphic color display

User interface : Screen touch

Power supply : 100-240 V; 47-63 Hz

RFID : Integrated for identifying test lot and calibration

Storage temperature : 10°C-40°C

Contact Now

Labnovation HbA1c Analyzer LD-100 Latest Analyzer For HbA1c Testing POCT With NGSP Certificated CV<3%

Intended Use

The LD-100 is a one-step operation HbA1c analyzer. For the measurement of glycated hemoglobin by the well-established borate affinity method. Small amount of sample and easy operation which is aimed to help manage diabetes for patients and professionals in laboratory, clinic and hospital. Flexible workflow, easy to use with lab-quality results. LD-100 helps you to be more efficient in your lab workflow.

NGSP Labnovation HbA1c Analyzer 4.3'' TFT Graphic Color Display For HbA1c Testing

• Boronate affinity test principle for HbA1c: The HbA1c assay has no interference from common Hb variants

• Ease of use: only a simple black/white calibration at start up, and the instrument is ready for use. Lot-specific test calibration by the operator is not necessary.

• Less than 3-minute test time

• Small sample size, Ideal for measurements of small series

• A compact, lightweight benchtop instrument;Portable — battery operation possible

• Minimal maintenance required

• Traceable to the IFCC Reference Method for HbA1c;Results reporting unit:IFCC units (mmol/mol) and NGSP units (%%).

Specification

Moder LD-100 Storage Condition

Analyzer:10-60℃;

Test Kit:2-8℃

Method Boronate Affinity Shelf-Life of Test Kit 9 months
Operating Type 1-Step, fully automatic Voltage 12VDC-3.33A
Measurement Time Less than 3 minutes Sample Volume
Sample Type Whole Blood Weight 800g
Measurement Range

HbA1c 4.0-15%(NGSP Unit)

eAG 68-385mg/dl(mmol/l)

Dimensions 192(L)×128(W)×108(H) mm
Storage environment:
Temperature:
20 ~55 C; Humidity: 10%~93%
Other Features USB Port, Lis Support
Working Principles
HbA1c Analyzer uses the (borate affinity) fluorescent immunoturbidimetry. Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently.
Calibration interface
When the instrument has been in use for a long time, if the deviation of the test value id found to be large, it is necessary to click the "Calibration" button and enter the calibration procedure to calibrate the instrument.

Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%
Performance Indicators
  • Result reporting unit : Glycated hemoglobin (HbA1c) is reported by default in IFCC units (mmol/mol) and NGSP units (%).
  • Accuracy: The accuracy is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision: Samples with a concentration of 4.0%-6.5% are detected, and the sample coefficient of variation (CV) of the test results is not more than 3%.
  • Stability: Within 8 hours after the instrument is turned on and stable, the same normal sample is tested, and the relative deviation of the test results is not more than ±3%.

Warning

  • The HbA1c Analyzer is designed and tested according to class A equipment in GB 4824. In the family environment, the equipment may cause radio interference, which requires protective measures.
  • It is forbidden to use this equipment beside strong radiation sources (such as unshielded radio frequency sources), otherwise it may interfere with the normal operation of the equipment.

Certificate

NGSP Labnovation HbA1c Analyzer 4.3'' TFT Graphic Color Display For HbA1c TestingNGSP Labnovation HbA1c Analyzer 4.3'' TFT Graphic Color Display For HbA1c Testing


Product Tags:

NGSP Labnovation HbA1c Analyzer

      

TFT Display Labnovation HbA1c Analyzer

      
Wholesale NGSP Labnovation HbA1c Analyzer 4.3'' TFT Graphic Color Display For HbA1c Testing from china suppliers

NGSP Labnovation HbA1c Analyzer 4.3'' TFT Graphic Color Display For HbA1c Testing Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Labnovation Technologies, Inc.
*Subject:
*Message:
Characters Remaining: (0/3000)