POCT Analyzer Fully Automated HbA1c Analyzer Detect Glycosylated Hemoglobin In Human Blood

Labnovation Technologies, Inc.
Contact Now

POCT Analyzer Fully Automated HbA1c Analyzer Detect Glycosylated Hemoglobin In Human Blood

Brand Name : LABNOVATION

Model Number : LD-100

Certification : IFCC, NGSP, CE

Place of Origin : Shenzhen, China

MOQ : 1

Price : Negotiation

Payment Terms : D/A, D/P, T/T

Supply Ability : 100/Day

Delivery Time : 15-20 working days

Packaging Details : Carton

Name : HbA1c Analyzer Fully Automated POCT Analyzer Detect Glycosylated Hemoglobin In Human Blood

Princip[le : Borate Affinity Method

Sample types : Whole blood

Sample Volume : 4μL

Dimension : 200mm(L)*130mm(W)*120mm(H)

Weight : 800g

Contact Now

HbA1c Analyzer Fully Automated POCT Analyzer Detect Glycosylated Hemoglobin In Human Blood

The HbA1c Analyzer Fully Automated POCT Analyzer Detect Glycosylated Hemoglobin In Human Blood LD-100 is an IVD(In Vitro Diagnostic Device) device for measuringHemoglobin A1c by the well established method of boronate affinity. It is able to analyze bothcapillary whole blood and venous blood. LD-100 is designedto help controlling diabetes and it is intended to be used by patients and professionals at home,laboratories, clinics and hospitals. Same as all diagnositc tests, do not make a definitivediagnosis of diabetes based on the result of a single test. A physician should make a diagnosisafter all clinical and laboratory findings are evaluated.


Feature

Boronate affinity Method: The HbA1c assay has no interference from common Hb variants

Ease of use: One-step operation the instrument is ready for use.

• Less than 3-minute test time

• A compact, lightweight instrument, Compact Size - To Minimize Space Requirements.

• With no need for bulky liquid reagents, LD-100 also free up more space in laboratories, clinics, blood banks, and other situations.

• Traceable to the IFCC Reference Method for HbA1c;Results reporting unit: IFCC units (mmol/mol) and NGSP units (%%).


Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%


Performance Parameters

  • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English; Abnormal alarm function.


Certificate

POCT Analyzer Fully Automated HbA1c Analyzer Detect Glycosylated Hemoglobin In Human BloodPOCT Analyzer Fully Automated HbA1c Analyzer Detect Glycosylated Hemoglobin In Human Blood


Product Tags:

4uL Fully Automated HbA1c Analyzer

      

800g Fully Automated HbA1c Analyzer

      

Human Blood POCT HbA1c Analyzer

      
Wholesale POCT Analyzer Fully Automated HbA1c Analyzer Detect Glycosylated Hemoglobin In Human Blood from china suppliers

POCT Analyzer Fully Automated HbA1c Analyzer Detect Glycosylated Hemoglobin In Human Blood Images